- Fast and accurate magnitude and phase calibration of vibration transducers
- Comparison calibration according to ISO 16063 – 21
- Primary magnitude and phase calibration (optional) according to ISO 16063 – 11
- Fast and accurate gain and phase calibration of preamplifiers
- Generation of complete certificates in Microsoft® Word according to ISO 17025
- Supervision of measuring instrumentation according to ISO 9000
- Quality assurance of sensors in manufacturing or use
| 特徴
- Very low expanded calibration uncertainty
- Automated calibration provides ease of use yet fault-proof results
- Frequency range 0.1 Hz to 25 kHz (optionally 100 kHz), depending on shaker and reference
- Calibrates practically all transducer types: charge, DeltaTron® (constant current IEPE), piezoresistive, variable capacitance, voltage, servo and electrodynamic
- Calibrates voltage and charge conditioners (using reference capacitor), (optional)
- Automated system calibration
- Choice of random or sine excitation
- User-defined test frequencies and levels depending on shaker and reference transducer
- Based on proven Brüel & Kjær PULSE™ Multi-analyzer technology
- Primary calibration according to ISO 16063 – 11 method 3 using commercial laser interferometer (optional, requires Type 5309 software)
- Brüel & Kjær back-up including staff training and system maintenance (optional)
- Typical calibration accuracy 10 – 2000 Hz: 0.7%; 2 – 5 kHz: 1.1%; 5 – 7 kHz: 1.2%; 7 – 10 kHz: 1.8% (one point reference calibration and including influence from the transducer to be calibrated)
- Software control by Vibration Transducer Calibration Software Type 5308
- Comprehensive database
- Customer database for handling of data and inventory following ISO 17025
- Tabular and graphical calibration results with flexible scaling
- Selection between SI or imperial units (g, in, in/s)
|
Vibration Transducer Calibration System Type 3629 is an easy-to-use, automatic calibration system that provides traceable calibration of a wide range of transducers.
The hardware for the basic system shown in Fig. 1 consists of a Portable PULSE front-end, which provides the necessary inputs and generator output, a power amplifier and a shaker. The front-end is connected via Ethernet to a standard PC (desktop or laptop). Furthermore, a Reference and a Working Standard transducer are required, with suitable preamplifiers if they are not DeltaTron transducers (transducers with constant current supply) or voltage output types. The standard reference transducer used in the mid-frequency range is Type 8305-001 with Charge to DeltaTron Converter Type 2647.
For a full Description and Specifications, see