用途- Binaural sound recording at the entrance to the human ear canal
- Sound recording where a vehicle’s driver wears the Binaural Microphone
- Binaural recordings where the influence of the test-person’s head and torso is important
- Sound recording of a helmeted person, for example, a motorcycle driver
- Psychoacoustic experiments requiring binaural sound recordings on human subjects
- Binaural recordings where the use of a traditional Head and Torso Simulator (HATS), for example, Sound Quality Head and Torso Simulator Type 4100, is impossible
- Evaluation of headphones and ear muffs on a human subject’s head/ears
| 特徴- Uses miniature, prepolarized condenser microphones that are positioned at the entrance to the ear canal and do not affect normal hearing capabilities
- Very lightweight: < 10 g down to the cable clip with the remaining cable
- Connects to and powered from DeltaTron® input (3 to 10 mA) via a BNC plug
- Free-field and diffuse-field corrections available as an ASCII table and built into the PULSE™ Sound Quality Software Type 7698
- Low equivalent noise level of 23 dB(A)
- Calibration adaptor for Sound Calibrator Type 4231
- TEDS (Transducer Electronic Data Sheet) available in Type 4101-A
|
Compliance with Standards
, CE-mark indicates compliance with: EMC Directive and Low Voltage Directive. C-Tick mark indicates compliance with the EMC requirements of Australia and New Zealand. Safety EN/IEC 61010 – 1: Safety requirements for electrical equipment for measurement, control and laboratory use. ANSI/UL 61010 – 1: Safety requirements for electrical equipment for measurement, control and laboratory use. EMC Emission EN/IEC 61000 – 6 – 3: Generic emission standard for residential, commercial and light industrial environments. EN/IEC 61000 – 6 – 4: Generic emission standard for industrial environments. CISPR 22: Radio disturbance characteristics of information technology equipment. Class B Limits. FCC Rules, Part 15: Complies with the limits for a Class B digital device. EMC Immunity EN/IEC 61000 – 6 – 1: Generic standards – Immunity for residential, commercial and light industrial environments. EN/IEC 61326: Electrical equipment for measurement, control and laboratory use – EMC requirements. RF field sensitivity: < 1.2 mV. Note: The above is only guaranteed using accessories listed in this Product Data sheet. Temperature IEC 60068– 2 – 1 & IEC 60068 – 2 – 2: Environmental Testing. Cold and Dry Heat. Operating Temperature: – 10 to + 45°C ( 14 to 113°F) Storage Temperature: – 20 to + 70°C (-4 to +158°F). Humidity IEC 60068 – 2 – 78: Damp Heat: 90% R.H. Non-condensing
General
The Binaural Microphone’s upper section comprises two 2 mm stainless-steel tubes. Because the microphone cables run through the inside of the tubes, either tube can be continuously bent without collapsing, and reshaped to suit test personnel. A miniature coaxial cable in one braid connects Microdot to BNC connectors. Additionally, a cable clip that can be attached to the test subject’s clothing is supplied to relieve pressure on both the microphone’s upper section and the test subject’s ear canal, freeing them from supporting any unnecessary...
For a full Description and Specifications, see
Product Data